7.3.3.5. Dismantling of the generator
Turn off a nut and remove the insulator of a conclusion.
Fig. 7.12. Removal of a plate of the rectifier
|
Remove a plate of the rectifier (fig. 7.12).
Turn off three nuts of fastening of a cover and uncover the generator from the vypryamitelny block.
Fig. 7.13. Removal of a cover of the brush holder
|
Uncover the brush holder (fig. 7.13).
Fig. 7.14. Removal of the brush holder and electronic regulator of tension
|
Unscrew five screws and remove the brush holder with a cover and the electronic regulator of tension (fig. 7.14).
Fig. 7.15. Removal of a sealing plate
|
Remove a sealing plate (fig. 7.15).
Fig. 7.16. Removal of a forward cover of the generator
|
Turn off four screws, remove the vypryamitelny block, four rubber insulators and a forward cover of the generator (fig. 7.16).
Fig. 7.17. Installation of special devices for removal of a pulley of a shaft of a rotor
|
Install special devices "1-A" and "1-B" on a generator pulley. Holding special 1-A adaptation a dynamometer key, tighten special 1-B adaptation (clockwise) (fig. 7.17).
Inhaling moment: 39 N · m.
ATTENTION
Make sure that special 1-A adaptation is reliably fixed on a rotor shaft.
|
Fig. 7.18. Installation of the generator on special 1-C adaptation
|
Clamp special 1-C adaptation, as shown in the figure 7.18, and install on it the generator.
Fig. 7.19. Otvorachivany nuts of fastening of a pulley of the generator special 1-A adaptation
|
To turn off a nut of fastening of a pulley, turn special 1-A adaptation in the direction shown in the figure 7.19.
ATTENTION
Not to damage a rotor shaft, turn off a nut of fastening of a pulley no more, than half way.
|
Remove the generator from special 1-C adaptation.
Fig. 7.20. Removal of special devices
|
Unscrew special 1-B adaptation and remove special devices "1-A" and "1-B" (fig. 7.20).
Turn off a nut of fastening of a pulley and a pulley of the generator.
Turn off a bolt, three nuts of fastening and remove a clip of a plate and a back cover of the generator.
Uncover the brush holder.
Unscrew two screws of fastening and remove the brush holder.
Unscrew three screws and remove tension regulator.
Unscrew four screws and remove the insulator of a conclusion.
Remove the rubber insulator.
Remove a rectifier plate.
Unscrew four nuts and remove a conducting clip.
Fig. 7.21. Removal of the vypryamitelny block
|
Using a stripper for bearings, remove the vypryamitelny block (fig. 7.21).
Remove a washer and take a rotor from a generator cover from the drive.