7.3.3.4. Installation of the generator (model with the engine 1 MZ-FE)

Install the generator.
Temporarily establish bolts of A and B.
Connect the generator wire socket.
Adjust a tension of a driving belt, tightening an adjusting bolt of Page.
Tighten bolts of A and B.
Inhaling moment:
bolt And – 58 N · m;
bolt In – 18 N · m.
Having checked a tension of a driving belt, finally hold on a bolt of Century.
Inhaling moment: 9.8 N · m.