7.3.3.2. Installation of the generator (model with the engine 1 and 2 AZ-FE)
Install the generator on an arm.
Establish a basic and lock bolt of fastening of the generator, acquire them, but do not twist finally.
Fig. 7.10. Installation of the generator (model with the engine 1 and 2 AZ-FE)
|
Connect the socket of the generator and fix an electrical wiring (fig. 7.10).
ATTENTION
Do not connect the generator socket, the generator is not installed yet.
|
Establish a driving belt.
Tighten basic and lock bolts of fastening of the generator.
Tighten bolts of fastening of a clip of a plait of wires and a bolt of fastening of a wire of the generator.
Inhaling moment:
- a basic bolt of M10 – 52 N · m;
- a lock bolt of M8 – 21 N · m;
- a bolt of fastening of a clip of a plait of wires – 8.4 N · m;
- a bolt of fastening of a wire of the generator – 9.8 N · m.