2f3e5fd0

3.3.11.1. Adjustment of the switch of situation parking / neutral

Install the situation switch a parking / neutral on a shaft of the manual valve.
Temporarily establish 2 bolts.
Place a new lock plate and tighten a nut.
Inhaling moment: 6,9 N · m.
Temporarily install the lever of a shaft of management.

Fig. 3.92. Adjustment of the switch of situation parking / neutral


Turn the lever counterclockwise against the stop, then turn the lever clockwise on 2 clicks (fig. 3.92).
Remove the lever of a shaft of management.

Fig. 3.93. Check of the switch of situation parking/neutral


Combine a groove with the basic line of a neutral (fig. 3.93).
Holding the switch on the place, tighten 2 bolts of fastening.
Inhaling moment: 5,4 N · m.

Fig. 3.94. Installation of a nut with a lock plate


Using the screw-driver, establish a nut with a lock plate (fig. 3.94).