2.4.8.2. Check of an axial side play of the conrod bearing

Fig. 2.318. Check of an axial side play of the conrod bearing


By means of the dial indicator, moving a rod back and forth on a conrod neck of a bent shaft, check an axial side play of the conrod bearing (fig. 2.318).
Standard axial gap – 0,15–0,30 mm.
The maximum axial gap – 0,35 mm.
If the axial gap is more than most admissible, replace a rod assembled. If necessary replace a bent shaft.