2.4.7.7. Installation of other components
Establish new laying and a final collector and evenly tighten six nuts of fastening in several passes the moment of an inhaling of 49 N · m.
Establish an arm of the pump of the amplifier of steering and wrap fastening bolts the moment of an inhaling of 43 N · m.
Establish a fixing plate on a head of the block of cylinders, having wrapped a fastening bolt the moment of an inhaling of 8 N · m.
Establish protection of an electrical wiring of the engine.
To establish a GRM drive belt cover No. 3, be convinced that laying of a cover was not stratified and did not crack. If necessary replace laying, having executed the following operations:
– using the screw-driver or a scraper, remove the remains of old laying;
Fig. 2.309. The scheme of the correct installation of laying on a GRM drive belt cover No. 3: 1 – laying; 2 – sealant; D – 335 mm; Е – 180 mm; F – 133 mm; G – 72 mm
|
– remove protective paper from new laying and paste laying, as shown in the figure 2.309.
Check whether new laying was well pasted.
Fig. 2.310. Installation of the cogged pulley of a bent shaft: 1 – pulley
|
Before installation of the cogged pulley of a bent shaft combine an adjusting spline on cranked to a shaft with a shponochny groove in a pulley (fig. 2.310).
Install the cogged pulley of a bent shaft of a guide of a belt (a rotation frequency sensor rotor) inside. Put a plate of the cogged pulley and wrap a bolt of fastening of a plate the moment of an inhaling of 8 N · m.
Establish a washer and wrap a roller-natyazhitelya bolt.
Check whether the roller-natyazhitel smoothly rotates.
Establish an intermediate pulley, tighten a fastening bolt the moment of an inhaling of 43 N · m also check whether the pulley smoothly rotates.
Fig. 2.311. Correct orientation of belts of pulleys of forward camshafts
|
Combine a spline on distributive to a shaft with a shponochny groove on a pulley and establish a pulley on a shaft. Install the cogged pulley of the forward camshaft of a guide of a belt inside (fig. 2.311).
Using the special tool, establish and tighten bolts of pulleys the moment of an inhaling of 125 N · m.
Fig. 2.312. Installation of the pump of cooling liquid
|
Install the pump of cooling liquid, having tightened four bolts and two nuts of fastening of the pump the moment of an inhaling of 8 N · m (fig. 2.312).
Establish a cover of a belt of the GRM drive and tighten six bolts the moment of an inhaling of 8 N · m.
Wrap spark plugs.
Install ignition coils.
Establish two new laying on an inlet branch pipe of a sitema of cooling. Connect a final branch pipe of the cooling system to a hose of restart-up of cooling liquid. Establish a final branch pipe, two washers and serially tighten two bolts and two nuts the moment of an inhaling of 15 N · m.
Establish an inlet collector, a fuel collector with nozzles, two washers and evenly tighten nine bolts and two nuts for several passes the moment of an inhaling of 15 N · m.
Establish the top part of an inlet collector assembled.
Establish an arm No. 1 of the engine and tighten two bolts the moment of an inhaling of 39 N · m.
Establish a rack of the top part of an inlet collector and tighten two bolts of its fastening the moment of an inhaling of 20 N · m.
Connect an electrical wiring and hoses.
Establish a protective cover of the engine.
Fill in cooling liquid.