2.4.2.2. Removal of a cover of a head of the block of cylinders
Fig. 2.222. Removal of protection of an electrical wiring
|
Disconnect two hoses of system of ventilation of a case from a cover of a head of the block of cylinders. Disconnect two clips of protection of a plait of wires against bolts of fastening of a cover No. 2 of a belt of the GRM drive. Turn off four nuts, remove consolidation of tubes of spark plugs. Turn off two nuts in a forward part of the engine and disconnect protection of an electrical wiring against a forward head of the block of cylinders (fig. 2.222).
Uncover a head of the block of cylinders and laying.
NOTE
To minimize oil leak, arrange consolidations of tubes of spark plugs in the sequence of removal for the subsequent their correct installation.
|