2.2.7.12. Check of a rod
Fig. 2.116. Check of a bend and twisting of a rod
|
Using special adaptation and the flat probe, check a rod bend. In the same way check twisting of a rod (fig. 2.116).
Limit bend on 100 mm of length – 0,05 mm.
Limit twisting on 100 mm of length – 0,15 mm.
If twisting is more than admissible, replace a rod assembled.