2.2.6.10. Check of internal diameters of the directing plugs of valves

Check internal diameters of the directing plugs of valves. By means of a nutromer measure internal diameters of the directing valves at three levels.
Internal diameter of the plug – 5,510–5,530 mm.
Make calculation by subtraction of size of diameter of a rod of the valve and size of internal diameter of the directing plug and establish thus the size of a standard side play between a rod of the valve and its guide.
Size of a standard side play:
admission – 0,025–0,060 mm;
release – 0,030–0,065 mm.
Maximum admission:
admission – 0,08 mm;
release – 0,10 mm.
If the gap is more than most admissible, replace the valve and the directing plug.