2f3e5fd0

2.2.5.9. Removal of a head of the block of cylinders, check of an axial side play of balancer shafts

Fig. 2.66. Order of weakening of bolts of fastening of a head of the block of cylinders


Using 10 mm a face key, in several passes, weaken and turn off ten bolts of fastening of a head of the block of cylinders in the sequence shown in the figure 2.66.

ATTENTION
Violation of the sequence of an otvorachivaniye of bolts can lead to damage of a head of the block of cylinders or to emergence of cracks in its case.


Fig. 2.67. Check of an axial side play of balancer shafts with the help of the dial indicator


Remove ten washers. By means of the screw-driver separate a head from the block of cylinders. Remove laying of a head of the block of cylinders. Remove the union of the oil heater. Remove the VVT-i oil filter. Measure by the dial indicator an axial side play when moving balancer shafts back and forth. (fig. 2.67).
Axial side play of balancer shafts:
standard – 0,050–0,090 mm;
maximum permissible – 0,090 mm.